ErrorID |
Validity |
Description |
Remedy |
|
|---|---|---|---|---|
TO1) |
Kin2) |
|||
16#8050 |
✓ |
- |
Illegal encoder number |
Technology version < V7.0: MC_SetSensor: At the "Sensor" parameter, enter a permissible number for the encoder. Technology version ≥ V7.0: MC_SetSensor: At the "Sensor" parameter, enter a permissible number (1, 2, 3, 4) for the encoder. MC_Home: At the "Sensor" parameter, enter a permissible number (0, 1, 2, 3, 4) used for an encoder. |
16#8051 |
✓ |
- |
Illegal number of the reference encoder |
Specify a permissible number of the reference encoder for parameter "MC_SetSensor.ReferenceSensor". If you call the instruction "MC_SetSensor" with parameter "Mode" = 0, enter a different number for the parameter "ReferenceSensor" than for the parameter "Sensor". |
16#8055 |
✓ |
- |
Bit masking not permitted at "MC_SetAxisSTW" |
Non-controllable bits are selected in the "STW1 BitMask" and "STW2 BitMask" bit masks. Only control permissible bits. |
16#805A |
✓ |
- |
Illegal value of the parameter to be changed |
At parameter "ParameterNumber", enter a permissible value for the index of the parameter to be changed. |
16#805B |
✓ |
- |
Error in the configuration of the hardware limit switch. |
Specify a valid tag at the input of the positive/negative HW limit switch. |
16#805C |
✓ |
- |
Illegal data type of the value to be written. |
Specify a valid data type at the parameter "Value". |
16#805D |
✓ |
- |
|
Configure the Ti, To, TDC communication times only if the PROFIdrive data connection via data block is configured. |
16#805E |
✓ |
- |
Invalid value for the tag "Actor.RemoveEnableReaction" |
Specify a permissible value for the stop mode at the "Remove enable" alarm response. |
16#805F |
✓ |
- |
Invalid state of the PROFIdrive state machine |
Call the "MC_WriteParameter" Motion Control instruction with the parameter in the Profidrive state S1 or S4. |
1) Applies to all technology objects with the exception of the Kinematics technology object.
2) Applies to the Kinematics technology object only.