Overview of IO-Link system

SIMATIC ET 200AL Manual Collection

ft:publication_title
SIMATIC ET 200AL Manual Collection
Product
ET 200AL
Version
V20
Publication date
10/2024
Language
zh-CN
Version
V20

Components

An IO-Link system consists of the following components:

  • IO-Link master

  • IO-Link device, for example:

    • Sensors/actuators

    • RFID readers

    • I/O modules

    • Valves

  • Unshielded 3-wire or 5-wire standard cables

  • Engineering tool for configuring and assigning parameters of IO-Link

Example plant with IO-Link

The figure below shows an example of plant architecture with IO-Link.

Figure 1. Plant architecture with IO-Link

The IO-Link master establishes the connection between the IO-Link devices and the automation system. If the IO-Link master is a component of the I/O system, it is installed either in the control cabinet or directly in the field as remote I/O in degree of protection IP65/67. The IO-Link master communicates by means of various fieldbuses or product-specific backplane buses. An IO-Link master can have multiple IO-Link ports (channels). An IO-Link device can be connected (point-to-point communication) to each port.

Engineering

The IO-Link system is engineered parallel to the overall automation system and can be embedded in it and intermeshed with it.