Error IDs 16#8070 - 16#807F (S7-1500, S7-1500T) - Motion Control

Using S7-1500 Motion Control (S7-1500, S7-1500T)

ft:publication_title
Using S7-1500 Motion Control (S7-1500, S7-1500T)
Product
Motion Control
Version
V21
Publication date
11/2025
Language
en-US
Error IDs 16#8070 - 16#807F

ErrorID

Validity

Description

Remedy

TO1)

Kin2)

16#8070

✓

-

Illegal value for leading value shift

Specify a permissible value for the leading value shift for parameter "PhaseShift".

16#8071

✓

-

The job cannot be executed because the axis is not in position-controlled mode.

Activate position-controlled mode.

16#8074

✓

-

The job cannot be executed because a "MC_Home" job is active.

During active or passive homing, an encoder switchover is rejected.

Wait until the "MC_Home" job is complete. Restart the job.

16#8075

✓

-

The job cannot be executed because no synchronization operation is active on the axis.

Switch on the synchronous operation function. Restart the job.

16#8076

✓

-

The job cannot be executed because synchronization is being simulated at the specified axis.

End the simulation of the synchronous operation. Restart the job.

16#8077

✓

-

The job cannot be executed because no "MC_GearInPos" or "MC_GearIn" job is waiting or active.

Switch on the synchronous operation function. Restart the job.

To desynchronize a camming, use the Motion Control instruction "MC_CamOut".

16#8078

✓

-

The job cannot be executed because no "MC_CamIn" job is waiting or active.

Switch on the camming function. Restart the job.

To desynchronize gearing, use the Motion Control instruction "MC_GearOut".

16#8079

✓

-

The job cannot be executed because a velocity gearing with "MC_GearInVelocity" is active.

A job to offset the leading or following value is only applicable during an active gearing or camming.

Following axis is in non-position-controlled operation.

Stop velocity gearing and restart "MC_GearInPos" job or "MC_CamIn" job.