Error IDs 16#0000 - 16#800F (S7-1500, S7-1500T) - Motion Control

Using S7-1500 Motion Control (S7-1500, S7-1500T)

ft:publication_title
Using S7-1500 Motion Control (S7-1500, S7-1500T)
Product
Motion Control
Version
V21
Publication date
11/2025
Language
en-US
Error IDs 16#0000 - 16#800F

ErrorID

Validity

Description

Remedy

TO1)

Kin2)

16#0000

✓

✓

No error

-

16#8001

✓

✓

A technology alarm (error at the technology object) has occurred during processing of the Motion Control job.

In the technology object data block, an error message is displayed at the "ErrorDetail.Number" tag.

You can find a list of the technology alarms and alarm responses in the section "Overview of the technology alarms".

16#8002

✓

-

Invalid specification of the technology object

  • Check the specification of the technology object at the parameter "Axis", "Master", "Slave", "OutputCam", "CamTrack", "MeasuringInput", "Cam" or "Interpreter".

  • With "MC_MeasuringInputCyclic": Specify a valid measuring input type for parameter "MeasuringInputType".

-

✓

Check the specification of the technology object for the "Axis" or "AxesGroup" parameter.

You can use a kinematics technology object only for the "AxesGroup" parameter.

16#8003

✓

✓

Invalid velocity specification

Specify a permissible value for the velocity for parameter "Velocity".

-

✓

Invalid velocity factor

Specify a permissible value for the velocity factor for the "VelocityFactor" parameter.

16#8004

✓

✓

Invalid acceleration specification

Specify a permissible value for the acceleration for the "Acceleration" parameter.

-

✓

Invalid acceleration factor

Specify a permissible value for the acceleration factor for the "AccelerationFactor" parameter.

16#8005

✓

✓

Invalid deceleration specification

Specify a permissible value for the deceleration for the "Deceleration" parameter.

-

✓

Invalid deceleration factor

Specify a permissible value for the deceleration factor for the "DecelerationFactor" parameter.

16#8006

✓

✓

Invalid jerk specification

Specify a permissible value for the jerk for parameter "Jerk".

-

✓

Invalid jerk factor

Specify a permissible value for the jerk factor for the "JerkFactor" parameter.

16#8007

✓

-

Invalid entry

Both the "JogForward" and "JogBackward" parameters are set to TRUE at the same time. The axis is braked at the last valid deceleration.

Reset both the "JogForward" parameter and the "JogBackward" parameter.

✓

-

Invalid direction specification

Specify a permissible value for the direction at the parameter "Direction" or "SyncDirection".

-

✓

Specify a permissible value for the motion direction for the "DirectionA" parameter.

16#8008

✓

-

Invalid distance specification

Set a permissible distance value for the "Distance" parameter.

-

✓

Invalid specification of the relative target coordinate

Specify permissible values for the relative target coordinate for the "Distance" parameter.

16#8009

✓

-

Invalid position specification

Set a permissible position value for the "Position" parameter.

-

✓

Invalid specification of the absolute target coordinate

Specify a permissible value for the absolute target coordinate in the "Position" parameter.

16#800A

✓

-

Invalid operating mode

Specify a permissible operating mode for parameter "Mode".

✓

✓

Invalid mode specification

Specify a permissible value for the mode for the "Mode" parameter.

16#800B

✓

-

Invalid stop mode specifications

Specify a permissible value for the stop mode at the "StopMode" parameter.

16#800C

✓

-

Only one instance of the instruction per technology object is allowed.

  • The instruction is called at multiple points in the user program with identical value for parameter "Axis", "Master", "Slave" or "Cam".

    Ensure that only one instruction with the value for parameter "Axis", "Master", "Slave" or "Cam" is called.

  • The error message can occur through the DB editor functions "Load snapshot as actual values" or "Load start values as actual values".

    Correct the error of the affected data block technology object by switching the CPU to STOP, re-compiling the affected data block, and loading it into the device.

16#800D

✓

✓

The job is not permitted in the current state. Technology objects are initialized.

When the operating state changes from STOP to RUN, the technology objects are initialized one after the other (STARTUP operating state). Depending on the number of technology objects used, this may take several application cycles.

Wait until the initialization of the technology objects is complete. Alternatively, extend the application cycle.

✓

-

The job is not permitted in the current state. "Restart" is executed.

While a "Restart" is being performed, the technology object cannot perform any jobs. Active jobs on the technology objects an output cam, cam track, measuring input or cam were canceled.

Wait until the "Restart" of the technology object is complete.

-

✓

While a restart is being performed, the technology object cannot perform any jobs. Active jobs were canceled.

Restarting the kinematics technology object can take up to one second.

Wait until the technology object restart is complete.

16#800E

✓

-

If the technology object is enabled, a "Restart" is not possible.

Before a "Restart", deactivate the technology object with "MC_Power.Enable" = FALSE.

Interpreter technology object:

"Restart" of the technology object not possible.

Other Motion Control job active.

The debug program mode performs a Motion Control job.

Wait until the active job is complete. Restart the job.

16#800F

✓

✓

The job cannot be executed because the technology object is locked.

  • Enable the technology object with "MC_Power.Enable" = TRUE. Restart the job.