Online access

Online access of the project

In the "Online access" folder of the project tree, you will find all active interfaces of your programming device/PC. Each interface icon provides you with information on the status. You can also display the accessible devices and display and edit the properties of an interface using the shortcut menu.

The following figure shows the "Online access" folder in the project tree:

"Online access" folder in the project tree

All interfaces installed in the programming device/PC are displayed in the "Online access" folder.

Show/hide interfaces

Use the function "Show/hide interfaces" to show or hide individual interfaces.

Status display for the interfaces

The current status of an interface is indicated by an icon to the right of the name. You can see the meaning of the icon in the tooltip.

Updating the list of accessible devices.

This function is available for each hardware interface of the programming device/PC. Software interfaces, such as a remote connection, do not offer this function.

Display more information

This function is available for each hardware interface of the programming device/PC after you have executed the function "Update accessible devices". You can find additional information in the detailed view of the overview window.

Devices connected via the respective interface with the programming device/PC

The type of the device and its status are displayed by the preceding icon.

Displaying or updating accessible devices

You have the following options if you want to display all devices accessible online on your programming device/PC:

  • Display of the accessible devices on a single interface of the programming device / PC in the project tree. In the project tree, you can also display additional information about the individual accessible devices.

  • Display of the accessible devices of all interfaces in a list.

See also:Displaying accessible devices

Overview of icons for accessible devices

The accessible devices are identified with an icon according to their type and status. The following is an overview of all icons and their meaning.

Icon for unidentified modules

This icon is displayed whenever the identification of a module is not yet complete or when the identification of a module was not successful, for example, because the required online data could not be read.

Icon for the following device types:

  • PLCs

  • SIMOCODE pro devices

  • IE/PB links

  • CPs of PC systems

  • SCALANCE head modules

  • S7-300 and S7-400 CPs

  • PROFINET IO devices and PROFINET CPs

  • SCALANCE modules and gateways that could not be identified

PROFINET IO devices, encoders, switchgear, sensors and identification systems that were replaced by similar devices because these could not be identified

Icon for the following device types:

  • HMI devices

  • PROFINET IO devices of the HMI type if these could not be identified and were therefore replaced by a similar device

PROFINET IO devices of the drive type that could not be identified and were therefore replaced by a similar device

PROFINET IO devices of the type development kit and network components that could not be identified and were therefore replaced by a similar device

PROFINET IO devices of the type TeleService adapter that could not be identified and were therefore replaced by a similar device