Function chart
The following values were configured in the configuration window Dynamics > General:
-
Acceleration: 10.0
-
Deceleration: 5.0
|
① |
The axis is braked by an MC_Halt command until it comes to a standstill. The axis standstill is signaled via "Done_2". |
|
② |
While an MC_Halt command is braking the axis, this command is aborted by another motion command. The abort is signaled via "Abort_2". |